Most studies of breast implant reconstruction count what happened to the implant. Few ask the patient how she feels about the result. A 2026 study from Ancona and Udine, in Italy, did both in the same 56 women. This article explains what it found.
In short
- 56 women had a mastectomy and an implant reconstruction in the same operation.
- Their own satisfaction with their breasts rose by 34.9 points out of 100.
- 94.6% of implants were still in place at follow-up.
- The better the result looked to independent surgeons, the more satisfied the patient was.
- ExaShape® was the matrix used in 44 of the 56 women. The results cover all 56 and are not split by matrix.
Who was in the study
Riccio, Zingaretti, De Francesco and colleagues looked back at 56 women treated one after another at the Marche University Hospital in Ancona.1 Each had a mastectomy and an implant reconstruction in the same operation. The team planned cancer safety, the look of the breast, the other breast and the patient’s own view together, as one plan. They call this an onco-aesthetic approach.
Where the skin was healthy enough, the implant was placed on top of the chest muscle (prepectoral). A matrix, a sheet of processed tissue that supports the implant, was used when the surgeon judged it was needed. In this group that matrix was ExaShape, a two-layer membrane made from bovine pericardium.
What patients said
Patients filled in the BREAST-Q before surgery and again at their last visit. The BREAST-Q is a standard questionnaire about how a woman feels about her breasts and her wellbeing. Each part is scored from 0 to 100, and higher is better.
Every score went up, and every rise was statistically significant.1
Two results stand out. Satisfaction with breasts rose by almost 35 points, which is a large change. And comfort in the chest also improved. That score often falls after a mastectomy. In an earlier ExaShape series, for example, it fell at six months.2 Here it rose by 19 points.
What surgeons saw
Experienced plastic surgeons who were not involved in the operations rated photographs of each result, using a standard four-step scale.
The surgeons’ ratings and the patients’ satisfaction matched very closely (a correlation of 0.904, where 1 would be a perfect match). In plain terms: when the breast looked better, the patient was more satisfied. That may sound obvious, but in many studies the two do not agree.
The other breast
24 of the 56 women (42.9%) also had surgery on the other breast in the same operation, to make the two match. Did that surgery, in itself, make patients more satisfied? No. Once the quality of the final result was taken into account, it made no separate difference.1
So operating on the other breast helps when it gives a better match, and adds nothing when it does not. It should be decided patient by patient.
Complications
12 of the 56 women (21.4%) had at least one complication. Most were problems with the skin or the nipple, which is expected with the anchor-shaped (Wise pattern) cuts used in every patient. Most were treated with dressings or a small local procedure.1
Checking the blood supply of the skin during surgery remains the most important safety step. See assessing the mastectomy flap.
What the study cannot tell us
This was a look back at 56 patients in one hospital, with no comparison group. The authors say so themselves.1 It cannot prove which part of the approach caused the good results, and it cannot credit them to the matrix.
What it means in practice
A reconstruction planned around how the breast will look, mostly on top of the muscle and mostly in one operation, gave large gains in how patients felt and kept almost all implants in place. And satisfaction followed the look of the result. That is where planning effort pays off.
For how the membrane is used, see ExaShape in practice.
References
- Riccio M, Zingaretti N, Aquinati A, et al. Oncoaesthetic breast reconstruction after mastectomy improves patient satisfaction and aesthetic outcomes. Clin Breast Cancer. 2026;26(10):134-146. doi:10.1016/j.clbc.2026.08.025
- Mazzocchi M, Sigorini G, Cerciello E, Barberini F. The use of ExaShape Bioshield Pocket in prepectoral breast reconstruction: a preliminary experience. Plast Reconstr Regen Surg. 2022;1(2):51-57. doi:10.57604/PRRS-064
Important information This article is general education, not medical advice. Tap to read the full medical, regulatory & legal notice.
This article is provided by Advanced Biomedical Concept for general informational and educational purposes only. It does not constitute medical, surgical, diagnostic, or other professional healthcare advice, and it is not a substitute for consultation with a suitably qualified healthcare professional. Reading it creates no doctor–patient or other professional relationship. Nothing here should be used to diagnose, treat, cure, or prevent any disease or condition, or to make decisions about medical care. Always seek the advice of a physician or other qualified provider with any questions about a medical condition or treatment, and never disregard or delay professional advice because of something you have read here.
Any reference to Advanced Biomedical Concept products (including ExaShape and ExaFat) is provided for general information only. These are medical devices intended to be used by appropriately trained healthcare professionals strictly in accordance with their applicable, current Instructions for Use (IFU). Regulatory status (including CE marking and classification under the EU Medical Device Regulation), market availability, and approved indications differ between countries and may change over time; a device referred to here may not be available or approved in your country. This content is not intended as, and must not be relied upon as, a statement or claim of safety, clinical performance, or efficacy beyond what is set out in the applicable IFU and current regulatory approvals. Product-specific information is directed at healthcare professionals and is not intended to promote, advertise, or offer any medical device to the general public where such promotion is restricted or prohibited by law.
Statements reflect information believed to be accurate at the date of publication and may be updated or corrected without notice. Any statements regarding the future are expectations or general views, not guarantees. Clinical outcomes depend on many individual factors, results vary from person to person, and no particular result is promised or implied. Where third-party studies, sources, or external links are referenced, they are provided for convenience and information only and do not imply endorsement, and Advanced Biomedical Concept is not responsible for their content.
To the fullest extent permitted by applicable law, Advanced Biomedical Concept and its officers, employees, contributors, and representatives (each acting in that capacity and on behalf of Advanced Biomedical Concept) accept no liability for any loss, injury, or damage of any kind arising directly or indirectly from use of, or reliance on, this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
Questions about this material can be directed to us via our contact page.
Last reviewed: November 16, 2026.